Control Voltage |
DC (5, 12, 24, 48), AC (12, 24, 48, 115, 230) 50/60 Hz. @ 5mA max. |
Load Voltage |
AC only (12, 24, 48, 115, 230) 50/60 Hz. |
Voltage Tolerances |
±20%. |
Timing Mode |
Flasher (opto-isolation between control & output voltage). |
Fixed Flash Rate |
Factory fixed at any rate from 1 to 250 flashes-per-minute (FPM) |
Tolerances On Fixed Timing |
±10% |
Adjustable Flash Rate |
1 to 60 flashes-per-minute and 5 to 250 flashes-per-minute. |
Purchase Tolerances On Adjustable Flash Rate |
Minimum Flash Rate - 15%, +0%. Maximum Flash Rate - 0%, +15% |
Repeatability Of Flashing Period |
±1% at stabilized operating voltage temperature. |
Recycle Time |
Operating voltage must be removed for a minimum of 200 milliseconds
to assure that the flasher and output circuits are reset. |
Output Rating |
70mA to 5A inductive with inrush currents to 40A for 8 milliseconds. |
Extending Rating |
Operation to 10A by mounting the timer heat sink base on a metal
surface and maintaining timer heat sink temperature to less than 90°C. |
Output Switch Characteristics |
3 volt drop across output switch when ON, 4mA leakage when OFF. |
Dielectric Strength |
1500Vrms all terminals to heat sink, 1500Vrms from control voltage
terminals to output terminals. Control voltage is optically isolated from
the output switching terminals. |
Operating Temperature |
-20°C to +85°C |