Timing Mode |
Interval countdown with dual outputs. |
Operating Voltage |
115V AC ±10% 50/60 Hz (-2) 230V AC ±10% 50/60 Hz (-3) @ 7W max. |
Timing Accuracy |
±1.0% of setting. |
Digital Display |
Four (4) digit red LED, 0.5 inch high characters displays remaining timing interval. |
Timing Cycle Memory |
4 preset times plus the last cycle time kept in non-volatile memory. Preset times
are accessed and programmed using the A, B, C, & D buttons. Each saved cycle
time is saved with an alarm time. |
Front Panel Switches |
Two for setting the cycle time, one for setting the alarm time, and one for starting
and stopping the timer. Four preset time buttons for programming and recalling
preset alarm and cycle times. Switches are raised membrane-type mounted on
black pc board material front panel. |
Audible Alarm |
The solid state alarm sounds at the end of the timing cycle until the Start/Stop switch
is pressed, and for 10 seconds after the programmed alarm time has elapsed in
a time cycle. Output rated for 103dB at 2 ft. |
Operating Temperature |
0°C to 70°C. |
Mounting |
2.62 sq. cutout accepts timer which is secured with rear attached bracket & nut.
Nut must not be tightened greater than 3 inch pounds, or product may be damaged.
6 (6) .25" Quick Connect terminals. |
Wiring |
Certified to UL Component-Appliance Controls US Standards ATNZ2, |