Call Toll Free: 800-457-4950
Home » Our Products » Controller » Delay On Make, Interval, Event Controller, Configurable Controller, Countdown

Configurable Countdown Timer

Model No. 5100 Description:
The 5100 is an Artisan 4970 controller with the addition of three preset times. This highly flexible countdown interval timer with digital display of timing controlling a set of high current output contacts. The timing cycle range can be configured for the following: 00:01-99:59 Minutes:Seconds, 00:01-99:59 Hours:Minutes, 0001-9999 Seconds, and 00.01-99.99 Seconds. The two arrow buttons on the front panel are used to set the time, the Up button increases the time and the Down decreases it. The longer a button is held down the faster the rate at which the time value will change, the time value rolls around at both ends of the time range. The A, B, and C buttons allow the user to store and recall up to 3 time values providing simplified switching between different cycle time values. The StartStop button performs multiple functions. Pressing the StartStop button while the timer is idle will energize the the output power relay contacts and the controller begins counting down the time on the display, once the display reaches 0 the contacts de-energize and the unit alarms per its configuration option. Pressing the Start Stop button while the controller is timing will pause the controller at the current time and de-energize the output relay contacts. Pressing the StartStop button while in pause mode causes the output relay to energize and the controller continues timing from the point at which it was paused. Should the StartStop switch be held down for longer than two seconds while in pause mode the controller will reset and the display will return to the original starting time. Should power fail during a timing cycle the controller remembers the last time value and will recover upon restoration of power dependant on its configuration. The 5100 always remembers the last interval time programmed and when first powered up resets to that time. The LED above the 4 digit display flashes during the timing cycle to indicate timing and is on continuously when th
Type Function Industries
Controller Delay On Make, Interval, Event Controller, Configurable Controller, Countdown Food Service, Medical-Dental

Operating Voltage 12VDC -10/+20%, 115VAC ±15%, 230VAC ±15%, 24VAC ±10%, 50/60 Hz for AC.
Current Consumption See table for operating current at nominal input voltages; Idle = display on, Timing = display & relay on, Standby = display off (option LP:02 selected)
Timing Accuracy ±0.5% of set time.
LED Digital Display Four digit red LED, 0.56" characters.
Timing Cycle Memory All data stored in non-volatile memory, 10 yr. min. retention with no power.
Audible Alarm Solid state alarm operating dependant on unit configuration.
Mounting 2.63 sq. cutout accepts timer which is secured with supplied bracket & nut. Mounting nut must be tightened to 3 inch pounds.
Wiring .25" Quick Connect terminals.

Terms & Conditions