Description
The model 4710T offers excellent transient protection and provides for reliable timing
control. The model 4710T is capable of controlling remote DC loads to 1 ampere at voltages
up to 150V DC. Closure of the Initiate Switch turns on the remote load circuit and resets
the timing to zero. Opening the initiate switch starts a preset timing period. The load
circuit remains energized until the timing period has elapsed, then de-energizes. If the
initiate switch is reclosed before the timing period has been completed, the timing cycle
will reset and the load circuit will remain energized. The model 4710T is available in
both fixed and adjustable models.
Specifications
| Operating Voltage |
22V-150V DC |
| Output Rating |
5 milliamperes to 1 ampere inductive with inrush
current to 15 amperes for 8 milliseconds. |
| Timing Mode |
Delay-On-Break,
initiate switch activated. |
| Timing Range Fixed |
0.1 - 4,500 seconds. |
| Operating Temperature |
-40 deg C to +85 deg C. |
| Repeatability of Timing |
+/- 1%. |
4710T Specifications , click to view, right
click - Save As ... to download
Ordering Information
| Model |
Operating Voltage |
Time Delay |
| 4710T-A (adjustable) |
-1 22-50VDC
-2 50-90VDC |
-1 0.1-6 sec
-4 15-900 sec
-2 1-100 sec -5 60-4500 sec
-3 10-600 sec |
| 4710T-F (fixed) |
Specify in seconds |
Example : 4710T-A-2-4 operates from 50-90
VDC with a delay of 15-900 seconds |